HS 5000 - Huvitz Slit Lamp
|
|
Clear images and wide views!
HS-5000
Cutting-edge optic technology assures both clear images
and wide views with the 5 step magnification control.
Various filters tailored for the most common diagnostic
scopes, and which assist with accurate diagnostic judgment. |
|
Find the difference by looking through the Huvitz Slit Lamp.
Experience the advanced diagnostic solution.
A perfect match -The integration of the high-end Slit Lamp HS-5000 & the Imaging System HIS-5000.
HS-5000 & HIS-5000 meet professional requirements for accurate diagnoses with the utmost convenience of data recording and management. The integrated system provides a new solution, |
 |
|
Illumination system brings extremely bright and vivid vision.
As a light source, a 12V, 30W high luminance halogen lamp gives you the highest vividness and the purist image.
Magnification Control System that can be used in various observations.
We use a drum style, five-step magnification control system.
You can get each field of the magnified clinical image, from low to high, very easily by just rotating the drum.
The faster and more stable IEEE 1394 interface method applied digital camera.
HS-5000 can achieve a maximum resolution of 1.45 M pixel with the IEEE 1394 interface method, which conducts image data faster and with more stability compared with the normal USB interface method. |
 | satisfying multi-tasking performance for diagnosis, data
|
Microscope can be operated easily and accurately.
HS-5000 gives you vivid images and a wide observation range with the global standard Galilean Converging Binocular optical system.
(6x :38.5mm, 10x :22.2mm, 16x :15.2mm, 25x :10.5mm, 40x :6.7mm)
Integrated control handle, easily operated one-handed.
The integrated control handle is simple to control.
For finer movement there is a trigger button mounted on the joystick.
Images can be stored simultaneously if the HS-5000 is connected to imaging devices. |


| recording and management.
|
Easily operated yellow filter for Fluoresceine
The Interior mounted yellow filter is easily operated by pushing a knob when you use Fluoresceine solution.
(Filters : Cobalt Blue, Red-Free, Heat Absorption, Grey, Yellow Filters) |
|
SPECIFICATIONS
|
SLIT ILLUMINATION
Slit Length (mm) 0.3~12 continuous
Slit Width (mm) 0~12 continuous
Slit Projection 1x
Aperture Diaphragms 12.5x
Filters Cobalt Blue, Red-Free,Grey and Heat Absorbing
Slit Rotation 0°~180°continuous
Angle of Incidence 0°, 5°, 10°, 15°, 20°
Patient’s Eye / Prism Surface Working Distance 80mm
MICROSCOPE
Microscope HS 5000 5x
Type Galilean Converging Binocular
Magnification 5 Position Rotating Drum
Eyepieces 12.5x
Total Magnifications 6x, 10x, 16x, 25x, 40x
Real Fields of View (mm) 38.5, 22.2, 15.2, 10.5, 6.7
Interpupilary Adjustment 55mm~80mm
BASE
Vertical Movement 28mm
Longitudinal Movement 78mm
Lateral Movement 98mm
Fine Base 10mm
Power Supply Free Voltage 100~240V AC
Voltage Frequency 50/60Hz
Power Consumption 70VA
Instrument Voltage 12V DC
Halogen Bulb 12V 30W
Fixation Point Bulb 3.4V 20mA |
 |
|
DIGITAL CAMERA
Image Sensor 1/2” Interline CCD
Image Size up to 1,388 x 1,036 pixels
Cell Size 4.65 ́m x 4.65́m
Resolution Depth 8bit or 12bit Raw RGB, YUV 4 : 2 : 2
Transmit Method IEEE 1394 (6pin)
Transmit Speed 400Mbps
Frame Rate 15fps, 7.5 fps, 3.75 fps
Lens Mount C-Mount
Photographing External Trigger or Software Trigger
Dimension 44mm (W) x 29mm (H) x 63mm (D)
Power Consumption less than 3W(12V DC, from IEEE 1394 Cable) |
|

|
RECOMMENDED COMPUTER SYSTEM
CPU Pentium IV, 2GHz
Memory 512MB (over 1GB recommended)
Video Card ATI Radeon 9200 (128MB) or similar
System
Microsoft Windows NT (with Service Pack 6),
Windows 2000 (with Service Pack 4),
Windows XP
Microsoft Internet Explorer 6 is need.
(Explorer 7 recommended)
Transmit Method
Standard IEEE1394a Firewire Port
OHCI 1.1 Compatible(with auxiliary 12Vpower
connector if connected to a laptop computer)
Monitor
LCD or CRT (minimum resolution 1,280 x1,024
pixels, over 1,600 x 1,200 pixels recommended)
|